کاتالوگ محصولات اصلاح ضریب توان هیمل,Himel Power Factor Correction,Himel Capacitor,Himel Capacitor Contactor Controller,Himel Reactor

سید علی موسوی چهارشنبه 12 مرداد 1401 - 18:39
کاتالوگ محصولات اصلاح ضریب توان هیمل,Himel Power Factor Correction,Himel Capacitor,Himel Capacitor Contactor Controller,Himel Reactor
کاتالوگ محصولات اصلاح ضریب توان هیمل

Himel Power Factor Correction,Himel Capacitor,Himel Capacitor Contactor Controller,Himel Reactor

کاتالوگ محصولات اصلاح ضریب توان هیمل

Power Factor Correction(Capacitor,Capacitor Contactor Controller,Reactor)

جهت دانلود کاتالوگ محصولات بر روی لینک زیر کلیک نمایید:

https://cdnfa.com/astshop/4540/uploads/catalogue/power-factor-correction-2022-04-01.pdf

 

The main consequences are: ● Need for oversizing of transmission and distribution networks by utilities, ● Increased voltage drops and sags along the distribution lines, ● Additional power losses. This results in increased electricity bills for industrial customers because of: ● Penalties applied by most utilities on reactive energy, ● Increased overall kVA demand, ● Increased energy consumption within the installations. Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability. For these reasons, there is a great advantage in generating reactive energy at the load level in order to prevent the unnecessary circulation of current in the network. This is what is known as “power factor correction”. This is obtained by the connection of capacitors, which produce reactive energy in opposition to the energy absorbed by loads such as motors. The result is a reduced apparent power, and an improved power factor P/S’ as illustrated in the diagram opposite. The power generation and transmission networks are partially relieved, reducing power losses and making additional transmission capacity available. Power Factor Correction Every electric machine needs active power (kW) and reactive power (kvar) to operate. The power rating of the installation in kVA is the combination of both: (kVA)² = (kW)² + (kvar)². The Power Factor has been defined as the ratio of active power (kW) to apparent power (kVA). Power Factor = (kW) / (kVA). The objective of Reactive Energy management is improvement of Power Factor, or “Power Factor Correction”. This is typically achieved by producing reactive energy close to the consuming loads, through connection of capacitor banks to the network. Quality and Reliability ● Advanced impregnation technology ensures the stability of parraffin fill-in: reliable lifecycle. ● 100% testing in manufacturing plant. ● Design and engineering with the highest international standards. Safety ● Explosion-proof equipment, and quick disconnection from power grid; ● No risk of oil leakage due to the application of microcrystalline wax as impregnation. Efficiency and Productivity ● Product development including innovation in ergonomics and ease of installation and connection. ● Specially designed components to save time on installation and maintenance. A Comprehensive Offer Power Factor Correction capacitor with and without reactor form part of a comprehensive offer of products perfectly coordinated to meet low-voltage power distribution needs

reference:

https://www.himel.com

بازخوردها
    ارسال نظر
    (بعد از تائید مدیر منتشر خواهد شد)
    • - نشانی ایمیل شما منتشر نخواهد شد.
    • - لطفا دیدگاهتان تا حد امکان مربوط به مطلب باشد.
    • - لطفا فارسی بنویسید.
    • - میخواهید عکس خودتان کنار نظرتان باشد؟ به gravatar.com بروید و عکستان را اضافه کنید.
    • - نظرات شما بعد از تایید مدیریت منتشر خواهد شد